YHLO iFlash 1200 Fully Automatic CLIA Analyzer
YHLO CLIA

YHLO iFlash 1200 Fully Automatic CLIA Analyzer

Fully automated chemiluminescence immunoassay analyzer designed for low to mid-volume laboratories, offering efficient testing with compact footprint and reliable performance.

  • checkFully automated CLIA analyzer with magnetic particle technology
  • checkThroughput up to 120 tests/hour with rapid result time
  • check16 sample positions with STAT priority function
  • check15 refrigerated reagent positions onboard
  • checkUp to 500 reaction vessels for continuous workflow
  • checkCompact design ideal for low to mid-volume laboratories
Request a Quote

Descriptions

iFlash 1200 is a fully automated chemiluminescence immunoassay analyzer designed for low to mid-volume laboratories, especially where space is limited. It provides an efficient and compact solution for routine immunoassay testing while maintaining high accuracy and reliability.

The system utilizes magnetic particle-based direct chemiluminescence technology with acridinium ester labeling, ensuring precise and sensitive detection of a wide range of biomarkers. It supports an extensive and continuously expanding test menu covering areas such as infectious diseases, tumor markers, hormones, autoimmunity, and metabolic disorders.

With a throughput of up to 120 tests per hour and a time to first result of approximately 13 minutes, the analyzer improves turnaround time while maintaining efficiency. The system features 16 sample positions with STAT capability, onboard refrigerated reagent storage, and continuous loading functionality, allowing uninterrupted operation.

Its automated workflow, low sample volume requirement, and integrated quality control features make iFlash 1200 a dependable solution for laboratories seeking performance, flexibility, and cost-effective immunoassay testing.

Technical Specifications

Analyzer Type
Fully Automated Chemiluminescence Immunoassay Analyzer
Throughput
Up to 120 tests/hour
Detection Principle
Magnetic particle-based direct chemiluminescence
Label
Acridinium ester
Sample Positions
16 with STAT capability
Sample Volume
5–150 µL
Reagent Positions
15 refrigerated positions (2–8°C)
Reaction Capacity
Up to 500 reaction vessels
Incubation Temperature
37°C ±0.3°C
Time to First Result
Approx. 13 minutes
Connectivity
LIS compatible
Operation
Random access and continuous loading

Product Brochure

Get technical details, installation requirements, and maintenance guidance for YHLO iFlash 1200 Fully Automatic CLIA Analyzer.

Loading brochure actions...

Related Diagnostic Solutions

Need Assistance with Lab Setup?

Our technical advisors can help configure the right diagnostic suite for your facility requirements.